Sign In | Join Free | My hardware-wholesale.com
China FUJIAN BOSS ELECTRICAL MACHINERY CO.,LTD. logo
FUJIAN BOSS ELECTRICAL MACHINERY CO.,LTD.
YOUR SATISFACTION IS OUR MISSION QUALITY IS OUR CULTURE
Active Member

6 Years

Home > Perkins Diesel Generator >

1000 KVA Diesel Driven Generator , Perkins Diesel Genset Automatically Start Up Function

FUJIAN BOSS ELECTRICAL MACHINERY CO.,LTD.
Contact Now

1000 KVA Diesel Driven Generator , Perkins Diesel Genset Automatically Start Up Function

Brand Name : Boss or OEM

Model Number : BS-P200

Certification : ISO , IEC , CE

Place of Origin : China

MOQ : 1 unit

Price : negotiable

Payment Terms : L/C, T/T, Western Union

Supply Ability : 50 units per month

Delivery Time : within 35 days

Packaging Details : Plastic Film Wrapping and Foam

Engine : Perkins

Alternator : Stamford , Leroy Somer , Meccalte

Range : 9-2250kva

Contact Now

50Hz Global Warranty Super Silent 800kw 1000kva Perkins Diesel Generator

Products features:

1. SPECIFICATIONS OF GEN-SET
1.1 Set Model BS-P1000
1.2 Prime at 50HZ, 40℃ ambient 800KW 1000KVA
1.3 Standby at 50HZ, 40℃ ambient 880KW 1100KVA
1.4 Rated Gen-set output 230/400V 50Hz
1.5 Rated Relative humidity ≤ 60 %
1.6 Dimension (L×W×H) 6050×2435×2585
1.7 Weight 9400kg
1.8 Fuel consumption 100% prime load 220l/hr
1.9 Noise Level at 7 (Normal/Super) 85dB
1.10 Structure of Gen-set The Gen-set adopt integrative structure, engine is fix on high strength steel basic frame, anti vibration instrument between the engine and basic frame, cooling fan have protecting cap, control cabinet and circuit breaker installed on Gen-set
1.11 Control system (Optional) Basic control panel or Advanced control panel with automatically start-up function and other function
2. SPECIFICATIONS OF ENGINE
2.1 Engine Brand Perkins
2.2 Engine Model 4008TAG2A
2.3 Governor/Class Electronic
2.4 Cylinder NO. 8
2.5 Engine build Vertical in-line
2.6 Fuel spray pattern direct injection
2.7 Aspiration Turbocharged
2.8 Cooling mode Radiator cooled (enclose water)
2.9 Bore and stroke 160 x 190 mm
2.10 Compression ratio 13.6:1
2.11 Displacement 30.561 litres
2.12 Engine Prime Power at 1500rpm 861KWm
2.13 Engine Standby Power at 1500rpm 947KWm
2.14 Start-up mode 24V, electric
2.15 Battery capacity 2 x 12 volts x 178 Ah
2.16 Starting/Min temperature /
2.17 Lubricating oil consumption Lubricating oil consumption less than 10% Fuel consumption
2.18 Lubrication oil capacity 153litres
2.19 Coolant capacity – radiator and engine (40℃) 149 litres
2.20 Exhaust temp – full load prime 438°C
2.21 Exhaust gas flow – full load prime 200m³/min
2.22 Exhaust gas back pressure max 3,0 kPa
2.23 Air flow – radiator (40℃ ambient) /
2.24 Pusher fan head (duct allowance) 40℃ /
2.25 Air intake – engine– full load prime 75m³/min
2.26 Standard Air intake temp 25℃
2.27 Fuel type #0 Diesel (Natural temperature)
2.28 Filter system Adopt whole changeable lubricating oil, fuel filter and air filter
2.29 Exhaust system Adopt industrial high efficiency silencer and flexible bellows
2.30 Engine derating – altitude /
2.31 Engine derating – temperature /
3. SPECIFICATIONS OF ALTENATOR
3.1 Alternator Model STAMFORD / LVI634E
3.2 Alternator Type A.C. Synchronous
3.3 Rated Voltage 230/400V
3.4 Rated Frequency 50HZ
3.5 Rated speed 1500 RPM
3.6 Voltage regulation mode Auto
3.7 Alternator voltage regulation ±0.5%
3.8 Exciting mode Brushless self exciting
3.9 Power factor 0.8 (lagging)
3.10 Phase & wires 3 phase 12 wires
3.11 Rated currency 1443.4A
3.12 Efficiency 0.942
3.13 Insulation class H
3.14 Protection class IP21
3.15 Single load step to NFPA110 100%
3.16 Standards IEC34-1
3.17 Max. Ambient Temperature 40℃
3.18 Min. Ambient Temperature - 20℃
3.19 Max. altitude 1000m
3.20 Weight 2260Kg

1000 KVA Diesel Driven Generator , Perkins Diesel Genset Automatically Start Up Function1000 KVA Diesel Driven Generator , Perkins Diesel Genset Automatically Start Up Function

1000 KVA Diesel Driven Generator , Perkins Diesel Genset Automatically Start Up Function

FAQ

Q : Do you offer OEM service?
A : Yes

Q : What is the difference between Prime power and Standby power?
A : Prime power is 12hours continous power,one hour 10% over load in every 12 running hours is allowed .
Standby power is the limit value of maximum output for emergency use . Overloading is prohibited
Q : What about the warranty
A : Guarantee for one year or 1000 hours (accord to whichever reach first) from ex-factory date .During the

guarantee period ,our company will provide the free easy damaged spare part for problems caused by our

quality of production or raw material except the damageable spare parts of diesel engine caused by

customer's incorrect man made operation . After expiration , our company provides cost parts maintenance

for gen-set.


Product Tags:

perkins power generator

      

perkins silent generator

      
China 1000 KVA Diesel Driven Generator , Perkins Diesel Genset Automatically Start Up Function wholesale

1000 KVA Diesel Driven Generator , Perkins Diesel Genset Automatically Start Up Function Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: FUJIAN BOSS ELECTRICAL MACHINERY CO.,LTD.
*Subject:
*Message: